A home-based system for detection of asthma in children

Asthma is becoming a very serious problem with every passing day, especially in children. However, it is very difficult to detect this disorder in them, since the breathing motion of children tends to change when they reach an age of 6. This, thus makes it very difficult to monitor their respiratory state easily. In this paper, I present a cheap non-contact alternative to the current methods that are available. This is using a stereo camera, that captures a video of the patient breathing at a frame rate of 30Hz.

For further processing, the captured video has to be rectified and converted into a point cloud. The obtained point clouds need to be aligned in order to have the output with respect to a common plane. They are then converted into a surface mesh. The depth is further estimated by subtracting every point cloud from the reference point cloud (taken as the first frame). The breathing signal obtained, however, when plotted with respect to real time produces a very noisy plot. This is filtered by determining the signal frequency by taking the Fast Fourier Transform of the signal.

The system was tested under 4 different breathing conditions: deep, shallow and normal breathing and breathing while coughing. On its success, it was tested with mixed breathing (combination of normal and shallow breathing) and was lastly compared with the output of the expensive 3DMD system. The comparison resulted in an output depth of 36.0661mm using the 3DMD and 38.4005mm using the stereo camera.